deps: update runc to 1.1.0

This updates vendored runc/libcontainer to 1.1.0,
and google/cadvisor to a version updated to runc 1.1.0
(google/cadvisor#3048).

Changes in vendor are generated by (roughly):

        ./hack/pin-dependency.sh github.com/google/cadvisor v0.44.0
        ./hack/pin-dependency.sh github.com/opencontainers/runc v1.1.0
        ./hack/update-vendor.sh
        ./hack/lint-dependencies.sh # And follow all its recommendations.
        ./hack/update-vendor.sh
        ./hack/update-internal-modules.sh
        ./hack/lint-dependencies.sh # Re-check everything again.

Co-Authored-By: Kir Kolyshkin <kolyshkin@gmail.com>
This commit is contained in:
Elana Hashman
2022-03-28 11:32:04 -07:00
parent 41830a1f79
commit 07af1bab70
245 changed files with 6520 additions and 5250 deletions

View File

@@ -105,7 +105,7 @@ func getSpecInternal(cgroupPaths map[string]string, machineInfoFactory info.Mach
}
// CPU.
cpuRoot, ok := getControllerPath(cgroupPaths, "cpu", cgroup2UnifiedMode)
cpuRoot, ok := GetControllerPath(cgroupPaths, "cpu", cgroup2UnifiedMode)
if ok {
if utils.FileExists(cpuRoot) {
if cgroup2UnifiedMode {
@@ -152,7 +152,7 @@ func getSpecInternal(cgroupPaths map[string]string, machineInfoFactory info.Mach
// Cpu Mask.
// This will fail for non-unified hierarchies. We'll return the whole machine mask in that case.
cpusetRoot, ok := getControllerPath(cgroupPaths, "cpuset", cgroup2UnifiedMode)
cpusetRoot, ok := GetControllerPath(cgroupPaths, "cpuset", cgroup2UnifiedMode)
if ok {
if utils.FileExists(cpusetRoot) {
spec.HasCpu = true
@@ -167,7 +167,7 @@ func getSpecInternal(cgroupPaths map[string]string, machineInfoFactory info.Mach
}
// Memory
memoryRoot, ok := getControllerPath(cgroupPaths, "memory", cgroup2UnifiedMode)
memoryRoot, ok := GetControllerPath(cgroupPaths, "memory", cgroup2UnifiedMode)
if ok {
if cgroup2UnifiedMode {
if utils.FileExists(path.Join(memoryRoot, "memory.max")) {
@@ -195,7 +195,7 @@ func getSpecInternal(cgroupPaths map[string]string, machineInfoFactory info.Mach
}
// Processes, read it's value from pids path directly
pidsRoot, ok := getControllerPath(cgroupPaths, "pids", cgroup2UnifiedMode)
pidsRoot, ok := GetControllerPath(cgroupPaths, "pids", cgroup2UnifiedMode)
if ok {
if utils.FileExists(pidsRoot) {
spec.HasProcesses = true
@@ -217,7 +217,7 @@ func getSpecInternal(cgroupPaths map[string]string, machineInfoFactory info.Mach
return spec, nil
}
func getControllerPath(cgroupPaths map[string]string, controllerName string, cgroup2UnifiedMode bool) (string, bool) {
func GetControllerPath(cgroupPaths map[string]string, controllerName string, cgroup2UnifiedMode bool) (string, bool) {
ok := false
path := ""

View File

@@ -35,6 +35,7 @@ import (
"k8s.io/klog/v2"
"github.com/google/cadvisor/container"
"github.com/google/cadvisor/container/common"
info "github.com/google/cadvisor/info/v1"
)
@@ -169,8 +170,7 @@ func (h *Handler) GetStats() (*info.ContainerStats, error) {
// file descriptors etc.) and not required a proper container's
// root PID (systemd services don't have the root PID atm)
if h.includedMetrics.Has(container.ProcessMetrics) {
paths := h.cgroupManager.GetPaths()
path, ok := paths["cpu"]
path, ok := common.GetControllerPath(h.cgroupManager.GetPaths(), "cpu", cgroups.IsCgroup2UnifiedMode())
if !ok {
klog.V(4).Infof("Could not find cgroups CPU for container %d", h.pid)
} else {

View File

@@ -157,13 +157,14 @@ func diskStatsCopy(blkioStats []cgroups.BlkioStatEntry) (stat []info.PerDiskStat
}
func NewCgroupManager(name string, paths map[string]string) (cgroups.Manager, error) {
config := &configs.Cgroup{
Name: name,
Resources: &configs.Resources{},
}
if cgroups.IsCgroup2UnifiedMode() {
path := paths[""]
return fs2.NewManager(nil, path, false)
return fs2.NewManager(config, path)
}
config := configs.Cgroup{
Name: name,
}
return fs.NewManager(&config, paths, false), nil
return fs.NewManager(config, paths)
}