.. that are not migrated to CSI in 1.26 *and* are based on a block device.
NFS and CephFS may use the same volume as several PVs and then mounting
with -o context won't work.
Currently, there are some unit tests that are failing on Windows due to
various reasons:
- paths not properly joined (filepath.Join should be used).
- Proxy Mode IPVS not supported on Windows.
- DeadlineExceeded can occur when trying to read data from an UDP
socket. This can be used to detect whether the port was closed or not.
- In Windows, with long file name support enabled, file names can have
up to 32,767 characters. In this case, the error
windows.ERROR_FILENAME_EXCED_RANGE will be encountered instead.
- files not closed, which means that they cannot be removed / renamed.
- time.Now() is not as precise on Windows, which means that 2
consecutive calls may return the same timestamp.
- path.Base() will return the same path. filepath.Base() should be used
instead.
- path.Join() will always join the paths with a / instead of the OS
specific separator. filepath.Join() should be used instead.
Currently, getNestedMountpoints sorts using sort.Strings, which would
sort the following strings in this exact order:
/dir/nested, /dir/nested-vol, /dir/nested.vol, /dir/nested/double, /dir/nested2
Because of this, "nested/double" is returned as well, even though it shouldn't
have been. This issue is worse on Windows, where the path separator is typically
the backslash.
This commit addresses this issue by checking if a nested mount point has been
previously seen or not.
Some of the unit tests cannot pass on Windows due to various reasons:
- fsnotify does not have a Windows implementation.
- Proxy Mode IPVS not supported on Windows.
- Seccomp not supported on Windows.
- VolumeMode=Block is not supported on Windows.
- iSCSI volumes are mounted differently on Windows, and iscsiadm is a
Linux utility.
Several reports exist (both with device plugins and CSI) that
kubelet w/ grpc-go sends invalid Authority header and some non
grpc-go servers reject these unix domain socket client connections.
grpc-go sets the Authority header correct when the dial address
is in a format where the its address scheme can be determined.
Instead of making changes to get the all server addresses to unix://
prefixed format, set grpc.WithAuthority("localhost") client connection
override to get the same result.
Signed-off-by: Mikko Ylinen <mikko.ylinen@intel.com>
Currently, there are some unit tests that are failing on Windows due to
various reasons:
- Windows file permissions do not work the same way as the Linux ones.
- cp does not exist on Windows, and xcopy should be used instead.
- Get-Item does not work for hidden files / folders like AppData, but
works if given the -Force flag.
These host paths have a well known location under /tmp/hostpath_pv
and are therefore safe to be labeled with the shared SELinux label.
Without this label, the mounted volumes cannot be accessed by the
container processes.
Signed-off-by: Mrunal Patel <mpatel@redhat.com>