Currently, there are some unit tests that are failing on
Windows due to various reasons:
- Different "File not found" error messages on Windows.
- Files need to be closed on Windows before removing them.
- The default RootHnsEndpointName (root-hnsendpoint-name) flag value is 'cbr0'
- On Windows, Unix Domain sockets are not checked in the same way in golang, which is why
hostutils_windows.go checks for it differently. GetFileType will return an error in this
case. We need to check for it, and see if it's actually a Unix Domain Socket.
This patch removes pkg/util/mount completely, and replaces it with the
mount package now located at k8s.io/utils/mount. The code found at
k8s.io/utils/mount was moved there from pkg/util/mount, so the code is
identical, just no longer in-tree to k/k.
This patch moves the HostUtil functionality from the util/mount package
to the volume/util/hostutil package.
All `*NewHostUtil*` calls are changed to return concrete types instead
of interfaces.
All callers are changed to use the `*NewHostUtil*` methods instead of
directly instantiating the concrete types.