Errors from staticcheck:
pkg/volume/azure_dd/azure_common.go:68:2: var winDiskNumFormat is unused (U1000)
pkg/volume/csi/csi_block.go:97:2: field volumeInfo is unused (U1000)
pkg/volume/csi/csi_block_test.go:56:6: func prepareBlockUnmapperTest is unused (U1000)
pkg/volume/csi/csi_client.go:108:2: const initialDuration is unused (U1000)
pkg/volume/csi/csi_client.go:109:2: const factor is unused (U1000)
pkg/volume/csi/csi_client.go:110:2: const steps is unused (U1000)
pkg/volume/csi/csi_client_test.go:83:8: this value of err is never used (SA4006)
pkg/volume/csi/csi_mounter.go:76:2: field options is unused (U1000)
pkg/volume/csi/csi_mounter_test.go:454:13: this value of err is never used (SA4006)
pkg/volume/csi/csi_plugin_test.go:766:16: this value of err is never used (SA4006)
pkg/volume/csi/csi_plugin_test.go:861:13: this value of err is never used (SA4006)
pkg/volume/csi/csi_plugin_test.go:1186:13: this value of err is never used (SA4006)
pkg/volume/csi/csi_plugin_test.go:1249:13: this value of err is never used (SA4006)
pkg/volume/csi/csi_test.go:305:5: the goroutine calls T.Fatalf, which must be called in the same goroutine as the test (SA2002)
pkg/volume/flexvolume/probe_test.go:67:10: this value of err is never used (SA4006)
pkg/volume/iscsi/iscsi_test.go:95:2: field attachCalled is unused (U1000)
pkg/volume/iscsi/iscsi_test.go:96:2: field detachCalled is unused (U1000)
pkg/volume/iscsi/iscsi_test.go:501:24: this value of err is never used (SA4006)
pkg/volume/iscsi/iscsi_util_test.go:159:2: this value of exist is never used (SA4006)
pkg/volume/local/local.go:351:57: argument devicePath is overwritten before first use (SA4009)
pkg/volume/plugins_test.go:119:2: this value of plug is never used (SA4006)
pkg/volume/plugins_test.go:125:2: this value of plug is never used (SA4006)
pkg/volume/quobyte/quobyte.go:474:23: this result of append is never used, except maybe in other appends (SA4010)
pkg/volume/quobyte/quobyte.go:477:23: this result of append is never used, except maybe in other appends (SA4010)
pkg/volume/quobyte/quobyte.go:480:23: this result of append is never used, except maybe in other appends (SA4010)
pkg/volume/rbd/rbd.go:886:2: field adminSecret is unused (U1000)
pkg/volume/rbd/rbd.go:887:2: field adminID is unused (U1000)
pkg/volume/rbd/rbd.go:888:2: field imageFormat is unused (U1000)
pkg/volume/rbd/rbd.go:889:2: field imageFeatures is unused (U1000)
pkg/volume/storageos/storageos.go:302:2: field secretName is unused (U1000)
pkg/volume/storageos/storageos_util_test.go:43:2: field apiAddr is unused (U1000)
pkg/volume/storageos/storageos_util_test.go:44:2: field apiUser is unused (U1000)
pkg/volume/storageos/storageos_util_test.go:45:2: field apiPass is unused (U1000)
pkg/volume/storageos/storageos_util_test.go:46:2: field apiVersion is unused (U1000)
pkg/volume/util/atomic_writer_test.go:756:49: argument err is overwritten before first use (SA4009)
pkg/volume/util/fsquota/common/quota_linux_common.go:37:2: const acct is unused (U1000)
pkg/volume/util/fsquota/common/quota_linux_common.go:38:2: const enforcing is unused (U1000)
pkg/volume/util/fsquota/project.go:168:31: identical expressions on the left and right side of the '==' operator (SA4000)
pkg/volume/util/fsquota/quota_linux.go:306:50: argument poduid is overwritten before first use (SA4009)
pkg/volume/util/fsquota/quota_linux_test.go:558:16: this value of err is never used (SA4006)
pkg/volume/util/subpath/subpath_linux.go:232:81: argument err is overwritten before first use (SA4009)
pkg/volume/util/subpath/subpath_linux_test.go:579:73: argument err is overwritten before first use (SA4009)
- Move from the old github.com/golang/glog to k8s.io/klog
- klog as explicit InitFlags() so we add them as necessary
- we update the other repositories that we vendor that made a similar
change from glog to klog
* github.com/kubernetes/repo-infra
* k8s.io/gengo/
* k8s.io/kube-openapi/
* github.com/google/cadvisor
- Entirely remove all references to glog
- Fix some tests by explicit InitFlags in their init() methods
Change-Id: I92db545ff36fcec83afe98f550c9e630098b3135
As #69219 outlines the unit tests in `csi_client_test.go` where not
testing the actual implementation of the `csiDriverClient` but was
testing the fake.
To fix this, we changed the `csiDriverClient` to use a
`nodeClientCreator` which is responsible for creating a new
`NodeClient`, a real one in prod and a fake one in the tests.
The setup of the gRPC connection has been pushed into that creator. The
node client uses that connection; that's transparent to the driver
client. It's the responsibility of the driver client to close the
connection when it is done with the node client. To achieve this, we
have the node client creator return a closer which handles the
connection teardown.
In the tests we now also check if the driver client actually calls
this closer, thus closing the gRPC connection.
Closes: #69219
Co-authored-by: Rosie Bloxsom <rbloxsom@pivotal.io>
Co-authored-by: Maria Ntalla <mntalla@pivotal.io>
This PR checks if NodeGetInfo returns error. If so, it returns
the error. Without this change, it always returns no error (nil)
regardless of whether NodeGetInfo returns error.
If our supported version is still at 0.X.X, then check
also the minor number. If our supported version is >= 1.X.X
then check only the major number.
Closes#58813