- make udev, runlevel, memory and wget separate files - rename os_utils to os_tools and move it to test_tools - remove ModuleRemoveMethod and set modprobe as default - fix regex in is_kernel_module_loaded method - remove get_sys_block_path - move get_block_device_names method to disk tools Signed-off-by: Katarzyna Treder <katarzyna.treder@h-partners.com>
110 lines
3.2 KiB
Python
110 lines
3.2 KiB
Python
#
|
|
# Copyright(c) 2019-2022 Intel Corporation
|
|
# Copyright(c) 2024 Huawei Technologies Co., Ltd.
|
|
# SPDX-License-Identifier: BSD-3-Clause
|
|
#
|
|
|
|
from enum import IntEnum
|
|
|
|
from core.test_run import TestRun
|
|
from test_tools.os_tools import SystemManagerType
|
|
|
|
|
|
class Runlevel(IntEnum):
|
|
"""
|
|
Halt the system.
|
|
SysV Runlevel: 0
|
|
systemd Target: runlevel0.target, poweroff.target
|
|
"""
|
|
runlevel0 = 0
|
|
poweroff = runlevel0
|
|
|
|
"""
|
|
Single user mode.
|
|
SysV Runlevel: 1, s, single
|
|
systemd Target: runlevel1.target, rescue.target
|
|
"""
|
|
runlevel1 = 1
|
|
rescue = runlevel1
|
|
|
|
"""
|
|
User-defined/Site-specific runlevels. By default, identical to 3.
|
|
SysV Runlevel: 2, 4
|
|
systemd Target: runlevel2.target, runlevel4.target, multi-user.target
|
|
"""
|
|
runlevel2 = 2
|
|
|
|
"""
|
|
Multi-user, non-graphical. Users can usually login via multiple consoles or via the network.
|
|
SysV Runlevel: 3
|
|
systemd Target: runlevel3.target, multi-user.target
|
|
"""
|
|
runlevel3 = 3
|
|
multi_user = runlevel3
|
|
|
|
"""
|
|
Multi-user, graphical. Usually has all the services of runlevel 3 plus a graphical login.
|
|
SysV Runlevel: 5
|
|
systemd Target: runlevel5.target, graphical.target
|
|
"""
|
|
runlevel5 = 5
|
|
graphical = runlevel5
|
|
|
|
"""
|
|
Reboot
|
|
SysV Runlevel: 6
|
|
systemd Target: runlevel6.target, reboot.target
|
|
"""
|
|
runlevel6 = 6
|
|
reboot = runlevel6
|
|
|
|
"""
|
|
Emergency shell
|
|
SysV Runlevel: emergency
|
|
systemd Target: emergency.target
|
|
"""
|
|
runlevel7 = 7
|
|
emergency = runlevel7
|
|
|
|
|
|
def get_system_manager():
|
|
output = TestRun.executor.run_expect_success("ps -p 1").stdout
|
|
type = output.split('\n')[1].split()[3]
|
|
if type == "init":
|
|
return SystemManagerType.sysv
|
|
elif type == "systemd":
|
|
return SystemManagerType.systemd
|
|
raise Exception(f"Unknown system manager type ({type}).")
|
|
|
|
|
|
def change_runlevel(runlevel: Runlevel):
|
|
if runlevel == get_runlevel():
|
|
return
|
|
if Runlevel.runlevel0 < runlevel < Runlevel.runlevel6:
|
|
system_manager = get_system_manager()
|
|
if system_manager == SystemManagerType.systemd:
|
|
TestRun.executor.run_expect_success(f"systemctl set-default {runlevel.name}.target")
|
|
else:
|
|
TestRun.executor.run_expect_success(
|
|
f"sed -i 's/^.*id:.*$/id:{runlevel.value}:initdefault: /' /etc/inittab")
|
|
TestRun.executor.run_expect_success(f"init {runlevel.value}")
|
|
|
|
|
|
def get_runlevel():
|
|
system_manager = get_system_manager()
|
|
if system_manager == SystemManagerType.systemd:
|
|
result = TestRun.executor.run_expect_success("systemctl get-default")
|
|
try:
|
|
name = result.stdout.split(".")[0].replace("-", "_")
|
|
return Runlevel[name]
|
|
except Exception:
|
|
raise Exception(f"Cannot parse '{result.output}' to runlevel.")
|
|
else:
|
|
result = TestRun.executor.run_expect_success("runlevel")
|
|
try:
|
|
split_output = result.stdout.split()
|
|
runlevel = Runlevel(int(split_output[1]))
|
|
return runlevel
|
|
except Exception:
|
|
raise Exception(f"Cannot parse '{result.output}' to runlevel.")
|