// Copyright (c) 2025 Ant Group
//
// SPDX-License-Identifier: Apache-2.0 or MIT
//
mod error;
use std::collections::HashMap;
pub use error::{Error, Result};
mod fs;
pub use fs::FsManager;
mod systemd;
pub use systemd::SystemdManager;
mod conv;
use oci_spec::runtime::LinuxResources;
use crate::systemd::SLICE_SUFFIX;
use crate::{CgroupPid, CgroupStats, FreezerState};
/// Check if the cgroups path is a systemd cgroup.
pub fn is_systemd_cgroup(cgroups_path: &str) -> bool {
let parts: Vec<&str> = cgroups_path.split(':').collect();
parts.len() == 3 && parts[0].ends_with(SLICE_SUFFIX)
}
/// Manage cgroups designed for OCI containers.
pub trait Manager: Send + Sync {
/// Add a process specified by its tgid.
fn add_proc(&mut self, tgid: CgroupPid) -> Result<()>;
/// Add a thread specified by its pid.
fn add_thread(&mut self, pid: CgroupPid) -> Result<()>;
/// Get the list of pids joint to the cgroups.
fn pids(&self) -> Result<Vec<CgroupPid>>;
/// Set the freezer cgroup to the specified state.
fn freeze(&self, state: FreezerState) -> Result<()>;
/// Remove the cgroups.
fn destroy(&mut self) -> Result<()>;
/// Set the resources to the cgroups.
fn set(&mut self, resources: &LinuxResources) -> Result<()>;
/// Get the cgroup path.
///
/// # Arguments
///
/// - `subsystem`: cgroup subsystem, for cgroup v1 the value should not
/// be empty, while for cgroup v2 the only valid value is `None`.
fn cgroup_path(&self, subsystem: Option<&str>) -> Result<String>;
/// Enable CPUs, topdown from root in cgroup hierarchy, this would be
/// useful for CPU hotplug in the guest.
///
/// The caller should update cgroup resources manually, in particular
/// cpuset, after this, in order to use the new CPUs (or avoid using
/// offline CPUs).
///
/// # Arguments
///
/// - `cpus`: online CPUs in the same format with `cat
/// /sys/devices/system/cpu/online`, e.g. "0-3,6-7".
fn enable_cpus_topdown(&self, cpus: &str) -> Result<()>;
/// Get cgroup stats.
fn stats(&self) -> CgroupStats;
/// Get the mappings of subsystems to their relative path. The full
/// path would be something like "{mountpoint}/{relative_path}". The
/// mappings of mountpoints see "mounts()".
fn paths(&self) -> &HashMap<String, String>;
/// Get the mappings of subsystems to their mountpoints. The full
/// path would be something like "{mountpoint}/{relative_path}". The
/// mappings of relative paths see "paths()".
fn mounts(&self) -> &HashMap<String, String>;
/// Indicate whether the cgroup manager is using systemd.
fn systemd(&self) -> bool;
/// Indicate whether the cgroup manager is using cgroup v2.
fn v2(&self) -> bool;
}
#[cfg(test)]
mod tests {
pub const MEMORY_512M: i64 = 512 * 1024 * 1024; // 512 MiB
pub const MEMORY_1G: i64 = 1024 * 1024 * 1024; // 1 GiB
pub const MEMORY_2G: i64 = 2 * 1024 * 1024 * 1024; // 2 GiB
#[macro_export]
macro_rules! skip_if_cgroups_v1 {
() => {
if !$crate::fs::hierarchies::is_cgroup2_unified_mode() {
eprintln!("Skipping test in cgroups v1 mode");
return;
}
};
}
#[macro_export]
macro_rules! skip_if_cgroups_v2 {
() => {
if $crate::fs::hierarchies::is_cgroup2_unified_mode() {
eprintln!("Skipping test in cgroups v2 mode");
return;
}
};
}
}