Fix the _reserved field in VirtioIommuConfig from [u8; 7] to
[u8; 3], correcting the struct size from 44 bytes to the
spec-mandated 40 bytes.
The virtio specification v1.2, Section 5.13.4 defines struct
virtio_iommu_config as 40 bytes total.
The kernel UAPI header linux/virtio_iommu.h matches this
layout with __u8 reserved[3] since kernel 5.17. Prior to that,
the struct was 36 bytes with no bypass field at all.
The incorrect [u8; 7] made the packed struct 44 bytes. Since
the struct is exposed to the guest, the guest saw a 44 byte
device specific configuration region instead of 40 bytes.
While well behaved guest drivers only access fields at known
offsets and would not observe data corruption from the extra
4 zero bytes at the tail, the oversized config region is a
spec violation.
The write_config path is not affected because it validates
the exact offset of the bypass field before allowing writes,
and the bypass field sits at offset 36 regardless of the
trailing reserved size.
Signed-off-by: Anatol Belski <anbelski@linux.microsoft.com>
This is a follow-up of [0].
# Advantages
- This saves dozens of unneeded clone()s across the whole code base
- Makes it much easier to reason about how parameters are used
(often we passed owned Arc/Rc versions without actually needing
ownership)
# Exceptions
For certain code paths, the alternatives would require awkward or overly
complex code, and in some cases the functions are the logical owners of
the values they take. In those cases, I've added
#[allow(clippy::needless_pass_by_value)].
This does not mean that one should not improve this in the future.
[0] 6a86c157af
Signed-off-by: Philipp Schuster <philipp.schuster@cyberus-technology.de>
On-behalf-of: SAP philipp.schuster@sap.com
Consuming `&Arc<T>` as argument is almost always an antipattern as it
hides whether the callee is going to take over (shared) ownership
(by .clone()) or not. Instead, it is better to consume `&dyn T` or
`Arc<dyn T>` to be more explicit. This commit cleans up the code.
The change is very mechanic and was very easy to implement across the
code base.
Signed-off-by: Philipp Schuster <philipp.schuster@cyberus-technology.de>
On-behalf-of: SAP philipp.schuster@sap.com
Fix clippy warning `uninlined_format_args` reported by rustc rustc
1.89.0 (29483883e 2025-08-04).
```console
warning: variables can be used directly in the `format!` string
--> block/src/lib.rs:649:17
|
649 | info!("{} failed to create io_uring instance: {}", error_msg, e);
| ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
= help: for further information visit https://rust-lang.github.io/rust-clippy/master/index.html#uninlined_format_args
= note: `#[warn(clippy::uninlined_format_args)]` on by default
help: change this to
|
649 - info!("{} failed to create io_uring instance: {}", error_msg, e);
649 + info!("{error_msg} failed to create io_uring instance: {e}");
|
```
Signed-off-by: Ruoqing He <heruoqing@iscas.ac.cn>
This streamlines the code base to follow best practices for
error handling in Rust: Each error struct implements
std::error::Error (most due via thiserror::Error derive macro)
and sets its source accordingly.
This allows future work that nicely prints the error chains,
for example.
So far, the convention is that each error prints its
sub error as part of its Display::fmt() impl.
Signed-off-by: Philipp Schuster <philipp.schuster@cyberus-technology.de>
On-behalf-of: SAP philipp.schuster@sap.com
Rust has a new way of constructing other error and clippy complains if
we are still using the older way to construct error message. Thus,
migrate to the new approach suggested by the clippy.
Warning from beta compiler:
error: this can be `std::io::Error::other(_)`
--> block/src/vhdx/mod.rs:142:17
|
| / std::io::Error::new(
| | std::io::ErrorKind::Other,
| | format!("Failed to update VHDx header: {e}"),
| | )
| |_________________^
|
= help: for further information visit
https://rust-lang.github.io/rust-clippy/master/index.html#io_other_error
help: use `std::io::Error::other`
std::io::Error::other(
format!("Failed to update VHDx header: {e}"),
Signed-off-by: Jinank Jain <jinankjain@microsoft.com>
Currently, Cloud Hypervisor does not set a VIRTIO_IOMMU_F_INPUT_RANGE
feature bit for the VirtIO IOMMU device, which, according to spec[1],
means that the guest may use the whole 64-bit address space is for
IOMMU purposes:
>If the feature is not offered, virtual mappings span over the whole
>64-bit address space (start = 0, end = 0xffffffff ffffffff)
As far as I am aware, there are currently no host platforms on
the market capable of addressing the whole 64-bit address space.
For example, I am currently working with a host platform that reports
39-bit address space for IOMMU purposes:
>DMAR: Host address width 39
When running a VFIO pass-through guest on such a platform, NVIDIA
driver in guest gets DMA mapping failures when working with large data,
and this results in Cloud Hypervisor exiting with the following error:
>cloud-hypervisor: 1501.220535s: <__iommu>
>ERROR:virtio-devices/src/thread_helper.rs:53 -- Error running worker:
>HandleEvent(Failed to process request queue : ExternalMapping(Custom
>{ kind: Other, error: "failed to map memory for VFIO container, iova
>0x7fff00000000, gpa 0x24ce25000, size 0x1000: IommuDmaMap(Error(22))"
>}))
Passing "--platform iommu_address_width=39" to Cloud Hypervisor built
with this change fixes this.
[1]: https://docs.oasis-open.org/virtio/virtio/v1.3/csd01/
virtio-v1.3-csd01.html#x1-5420006
Signed-off-by: Nikolay Edigaryev <edigaryev@gmail.com>
Remove an erroneous optimisation that used the page size mask to reduce
the range to iterate through on the set of mappings. This doesn't work
as the virtio-iommu ranges are larger than a single page. This may have
worked in the past when the mappings were limited to a single page.
Signed-off-by: Rob Bradford <rbradford@rivosinc.com>
By introducing `imports_granularity="Module"` format strategy,
effectively groups imports from the same module into one line or block,
improving maintainability and readability.
Signed-off-by: Ruoqing He <heruoqing@iscas.ac.cn>
Historically the Cloud Hypervisor coding style has been to ensure that
all imports are ordered and placed in a single group. Unfortunately
cargo fmt has no support for ensuring that all imports are in a single
group so if whitespace lines were added as part of the import statements
then they would only be odered correctly in the group.
By adopting "group_imports="StdExternalCrate" we can enforce a style
where imports are placed in at most three groups for std, external
crates and the crate itself. Choosing a style enforceable by the tooling
reduces the reviewer burden.
Signed-off-by: Rob Bradford <rbradford@rivosinc.com>
Properly detach a device from a domain if that device is already
attached to another domain on an attach request (following section
5.13.6.3.2 of the virtio-iommu spec). Resolves nested virtualization
reboot.
Signed-off-by: Andrew Carp <acarp@crusoeenergy.com>
Ensures that any endpoints already attached to the domain are properly
mapped to a new endpoint on said endpoint's attach request. This is done
by search for all previous mappings in the domain and then issuing map
requests for the newly attached endpoint.
Signed-off-by: Andrew Carp <acarp@crusoeenergy.com>
According to the virtio iommu spec (section 5.13.6.6), all mappings
within the entire range from virt_start to virt_end in an unmap
request must be removed. This change adds this functionality,
iterating through all mappings that fall within an unmap request
for that domain and removing them.
Signed-off-by: Andrew Carp <acarp@crusoeenergy.com>
This change is important to do a proper resource cleanup. We decided
to do this repetitive approach as VirtioCommon can't implement Drop
without major changes to the corresponding code. Also, devices such as
Net can't easily use the epoll_threads-abstraction from VirtioCommon as
it has multiple threads with different semantics.
Signed-off-by: Philipp Schuster <philipp.schuster@cyberus-technology.de>
The information about the identifier related to a Snapshot is only
relevant from the BTreeMap perspective, which is why we can get rid of
the duplicated identifier in every Snapshot structure.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Following the new restore design, it is not appropriate to set every
virtio device threads into a paused state after they've been started.
This is why we remove the line of code pausing the devices only after
they've been restored, and replace it with a small patch in every virtio
device implementation. When a virtio device is created as part of a
restored VM, the associated "paused" boolean is set to true. This
ensures the corresponding thread will be directly parked when being
started, avoiding the thread to be in a different state than the one it
was on the source VM during the snapshot.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Following the new design proposal to improve the restore codepath when
migrating a VM, all virtio devices are supplied with an optional state
they can use to restore from. The restore() implementation every device
was providing has been removed in order to prevent from going through
the restoration twice.
Here is the list of devices now following the new restore design:
- Block (virtio-block)
- Net (virtio-net)
- Rng (virtio-rng)
- Fs (vhost-user-fs)
- Blk (vhost-user-block)
- Net (vhost-user-net)
- Pmem (virtio-pmem)
- Vsock (virtio-vsock)
- Mem (virtio-mem)
- Balloon (virtio-balloon)
- Watchdog (virtio-watchdog)
- Vdpa (vDPA)
- Console (virtio-console)
- Iommu (virtio-iommu)
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Considering error messages will be mostly nested, ensuring no
punctuation at the end will make the error log more readable.
Signed-off-by: Bo Chen <chen.bo@intel.com>
The the number of queues and associated events is known and fixed. We
can define and use each of them explicitly and avoid using vector (and
hence direct indexing), which is cleaner and slightly more efficient.
Also, this refactoring makes it clearer that we are not handling "event
queue" events (as "_event_queue" is not being used intentionally).
Signed-off-by: Bo Chen <chen.bo@intel.com>
In this way, the virtio-iommu code can properly report an error when
a wrong number of queues is provided, instead of triggering an
out-of-bound error.
Signed-off-by: Bo Chen <chen.bo@intel.com>
Now that we rely on pop_descriptor_chain() rather than iter() to iterate
over a queue, there's no more borrow on the queue itself, meaning we can
invoke add_used() directly for the iteration loop. This simplifies the
processing of the queues for each virtio device, and bring some possible
performance improvement given we don't have to iterate twice over the
list of descriptors to invoke add_used().
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Using pop_descriptor_chain() is much more appropriate than iter() since
it recreates the iterator every time, avoiding the queue to be borrowed
and allowing the virtio-net implementation to match all the other ones.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The new virtio-queue version introduced some breaking changes which need
to be addressed so that Cloud Hypervisor can still work with this
version.
The most important change is about removing a handle to the guest memory
from the Queue, meaning the caller has to provide the guest memory
handle for multiple methods from the QueueT trait.
One interesting aspect is that QueueT has been widely extended to
provide every getter and setter we need to access and update the Queue
structure without having direct access to its internal fields.
This patch ports all the virtio and vhost-user devices to this new crate
definition. It also updates both vhost-user-block and vhost-user-net
backends based on the updated vhost-user-backend crate. It also updates
the fuzz directory.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Instead of passing separately a list of Queues and the equivalent list
of EventFds, we consolidate these two through a tuple along with the
queue index.
The queue index can be very useful if looking for the actual index
related to the queue, no matter if other queues have been enabled or
not.
It's also convenient to have the EventFd associated with the Queue so
that we don't have to carry two lists with the same amount of items.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Improve the request parsing/handling code by allowing an error status to
be returned back to the guest driver before we return an error
internally.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Extend the Domain structure to store the information about each domain
being in bypass mode or not. Based on this new information, the address
translation of the virtio devices is performed according to the bypass
mode of each domain. And both MAP/UNMAP requests are generating errors
in case the domain has been previously set to bypass mode.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
In anticipation for associating more than mappings with a domain, we
factorize the list of mappings associated with a domain behind a
dedicated Domain structure. We also update the field name so that it
reads better in the code.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Exposing the VIRTIO_IOMMU_F_BYPASS_CONFIG feature to the guest, which
allows to update the bypass global knob through virtio configuration.
Based on the value of this global knob, the address translations for
endpoints that have not been added to a domain is allowed with a simple
identity mapping.
By default, we enable the bypass mode for all endpoints that are not
attached to any domain.
Fixes#3987
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Based on the VIRTIO specification, we must be able to support multiple
endpoints per domain. This is fixed along with the introduction of some
simplification regarding how we can retrieve the external mapping
directly based on the endpoint.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>