mirror of
https://github.com/ibm-s390-linux/s390-tools.git
synced 2026-08-05 02:14:52 +00:00
zpwr: Add man page for zpwr tool
Add man page for zpwr tool and its usage. Reviewed-by: Jan Höppner <hoeppner@linux.ibm.com> Signed-off-by: Sumanth Korikkar <sumanthk@linux.ibm.com> Signed-off-by: Jan Höppner <hoeppner@linux.ibm.com>
This commit is contained in:
committed by
Jan Höppner
parent
6004a7029c
commit
05f0aeb61e
@@ -15,7 +15,9 @@ zpwr: $(OBJECTS) $(rootdir)/libutil/libutil.a -lm
|
||||
|
||||
install: all
|
||||
$(INSTALL) -d -m 755 $(DESTDIR)$(USRBINDIR)
|
||||
$(INSTALL) -d -m 755 $(DESTDIR)$(MANDIR)/man1
|
||||
$(INSTALL) -g $(GROUP) -o $(OWNER) -m 755 zpwr $(DESTDIR)$(USRBINDIR)
|
||||
$(INSTALL) -g $(GROUP) -o $(OWNER) -m 644 man/zpwr.1 $(DESTDIR)$(MANDIR)/man1
|
||||
|
||||
clean:
|
||||
rm -f *.o *~ zpwr core
|
||||
|
||||
232
zpwr/man/zpwr.1
Normal file
232
zpwr/man/zpwr.1
Normal file
@@ -0,0 +1,232 @@
|
||||
.\" Copyright 2025 IBM Corp.
|
||||
.\" s390-tools is free software; you can redistribute it and/or modify
|
||||
.\" it under the terms of the MIT license. See LICENSE for details.
|
||||
.\"
|
||||
.ds c \fBzpwr\fP
|
||||
.TH zpwr 1 "Feb 2025" "s390-tools" zpwr
|
||||
.SH NAME
|
||||
zpwr \- Display power readings of a partition and central processor complex
|
||||
(CPC) on an IBM Z or LinuxONE server.
|
||||
.SH SYNOPSIS
|
||||
.sp
|
||||
.nf
|
||||
\fIzpwr\fR
|
||||
[\-d <NUMBER> | \-\-delay=<NUMBER>] [\-c <NUMBER> | \-\-count=<NUMBER>]
|
||||
[\-\-format=<STRING>]
|
||||
[\-s | \-\-stream]
|
||||
[\-v | \-\-version]
|
||||
[\-h | \-\-help]
|
||||
.fi
|
||||
.SH DESCRIPTION
|
||||
.sp
|
||||
zpwr displays power readings of a partition and central processor complex
|
||||
(CPC) on an IBM Z or LinuxONE server.
|
||||
.sp
|
||||
Partition readings include CPU, storage and I/O power readings. It specifies
|
||||
the number of units allocated to the configuration at the time the reading was
|
||||
taken.
|
||||
.sp
|
||||
CPC readings include total, unassigned resources and infrastructure power
|
||||
readings.
|
||||
.sp
|
||||
Power reading units are automatically presented in a human readable format,
|
||||
whereas complex formats like json, csv, json-seq, pairs display the power
|
||||
readings in microwatts.
|
||||
.sp
|
||||
CPC power readings can be retrieved only when the required authorization was
|
||||
set for the LPAR. Enable the required authorization by setting "Global
|
||||
Performance Data" in LPAR's activation profile.
|
||||
.sp
|
||||
If the power readings cannot be retrieved, the power readings return an empty
|
||||
string or null in complex formats, and the power readings are not displayed in
|
||||
human readable format.
|
||||
.SH OPTIONS
|
||||
.PP
|
||||
\-\-format=<STRING>
|
||||
.RS 4
|
||||
Retrieve power readings in the following formats: json, csv,
|
||||
json-seq or pairs. If no format is specified in the command, the output will
|
||||
default to the human readable format.
|
||||
.sp
|
||||
When the format is json, csv, json-seq or pairs, the power readings are
|
||||
displayed in microwatts.
|
||||
.RE
|
||||
.PP
|
||||
\-d, \-\-delay
|
||||
.RS 4
|
||||
Retrieve power readings after specified delay in seconds has elapsed.
|
||||
.RE
|
||||
.PP
|
||||
\-c <NUMBER>, \-\-count=<NUMBER>
|
||||
.RS 4
|
||||
Required number of power readings.
|
||||
.sp
|
||||
The \-\-count option can only be used in conjunction with \-\-stream or
|
||||
\-\-delay option.
|
||||
.RE
|
||||
.PP
|
||||
\-s, \-\-stream
|
||||
.RS 4
|
||||
Retrieve power readings in stream mode. A new power reading will be displayed
|
||||
only after an interval has elapsed since the last power reading request.
|
||||
The interval is automatically calculated in stream mode.
|
||||
.sp
|
||||
The \-\-stream and \-\-delay options are mutually exclusive.
|
||||
.RE
|
||||
.PP
|
||||
\-v, \-\-version
|
||||
.RS 4
|
||||
Print version information.
|
||||
.RE
|
||||
.PP
|
||||
\-h, \-\-help
|
||||
.RS 4
|
||||
Print usage information.
|
||||
.RE
|
||||
.SH OUTPUT
|
||||
.B Iteration
|
||||
.RS 4
|
||||
Iteration number of the current power readings. If the power reading is
|
||||
requested before the time interval has elapsed, cached power readings might be
|
||||
returned. The iteration number helps to determine if the cached power readings
|
||||
are provided.
|
||||
.RE
|
||||
.PP
|
||||
.B Time
|
||||
.RS 4
|
||||
The time at which power readings were taken, expressed in human readable format.
|
||||
.RE
|
||||
.PP
|
||||
.B Time epoch
|
||||
.RS 4
|
||||
The time at which power readings were taken, expressed in epoch time.
|
||||
.PP
|
||||
.B sec
|
||||
.RS 4
|
||||
The number of seconds elapsed since the Unix epoch.
|
||||
.RE
|
||||
.PP
|
||||
.B nsec
|
||||
.RS 4
|
||||
The number of nanoseconds elapsed since the last full seconds.
|
||||
.RE
|
||||
.RE
|
||||
.PP
|
||||
.B Update interval
|
||||
.RS 4
|
||||
Indicates the time interval in nanoseconds after which new power readings are
|
||||
available. If the power readings is requested before the time interval has
|
||||
elapsed, cached power readings might be returned.
|
||||
.RE
|
||||
.PP
|
||||
.B CPU
|
||||
.RS 4
|
||||
CPU power reading of a partition.
|
||||
.RE
|
||||
.PP
|
||||
.B Storage
|
||||
.RS 4
|
||||
Storage power reading of a partition.
|
||||
.RE
|
||||
.PP
|
||||
.B I/O
|
||||
.RS 4
|
||||
I/O power reading of a partition.
|
||||
.RE
|
||||
.PP
|
||||
.B Total
|
||||
.RS 4
|
||||
Specifies number of units for all electrical and mechanical components of the
|
||||
system.
|
||||
.RE
|
||||
.PP
|
||||
.B Unassigned Resources
|
||||
.RS 4
|
||||
Specifies number of units for all types of resources in the standby state or
|
||||
reserved state at the time the reading was taken.
|
||||
.RE
|
||||
.PP
|
||||
.B Infrastructure
|
||||
.RS 4
|
||||
Specifies number of units for all subsystems in the CPC which do not provide
|
||||
CPU, storage or I/O resources to partitions.
|
||||
.RE
|
||||
.SH "EXAMPLES"
|
||||
1. Display power readings in human readable format.
|
||||
.nf
|
||||
.ft CW
|
||||
# zpwr
|
||||
LPAR CPU: 140.00 W
|
||||
LPAR Storage: 1.72 W
|
||||
LPAR I/O: 40.00 W
|
||||
|
||||
CPC Total: 15.40 kW
|
||||
CPC Unassigned Resources: 7.48 kW
|
||||
CPC Infrastructure: 5.31 kW
|
||||
|
||||
Update interval: 10.00 s
|
||||
.ft
|
||||
.fi
|
||||
.sp 1
|
||||
2. Perform two power measurements with a delay of 10 seconds and output the
|
||||
data in json format.
|
||||
.nf
|
||||
.ft CW
|
||||
# zpwr --format json --delay 10 --count 2
|
||||
{
|
||||
"meta": {
|
||||
"api_level": "1",
|
||||
"version": "2.36.0-build-20250107",
|
||||
"host": "lpar001",
|
||||
"time_epoch": "1736316898",
|
||||
"time": "2025-01-08 07:14:58+0100"
|
||||
},
|
||||
"zpwr": [
|
||||
{
|
||||
"iteration": "0",
|
||||
"time": "2025-01-08 07:14:58+0100",
|
||||
"time_epoch_sec": "1736316898",
|
||||
"time_epoch_nsec": "10935887",
|
||||
"update_interval": "10000000000",
|
||||
"lpar": [
|
||||
"cpu": "140000000",
|
||||
"storage": "1719200",
|
||||
"io": "40000000"
|
||||
],
|
||||
"cpc": [
|
||||
"total": "15406000000",
|
||||
"unassigned_resources": "7578848100",
|
||||
"infrastructure": "5283946300"
|
||||
]
|
||||
},
|
||||
{
|
||||
"iteration": "1",
|
||||
"time": "2025-01-08 07:15:08+0100",
|
||||
"time_epoch_sec": "1736316908",
|
||||
"time_epoch_nsec": "11113153",
|
||||
"update_interval": "10000000000",
|
||||
"lpar": [
|
||||
"cpu": "140000000",
|
||||
"storage": "1719200",
|
||||
"io": "40000000"
|
||||
],
|
||||
"cpc": [
|
||||
"total": "15401000000",
|
||||
"unassigned_resources": "7569928400",
|
||||
"infrastructure": "5284866000"
|
||||
]
|
||||
}
|
||||
]
|
||||
}
|
||||
.ft
|
||||
.fi
|
||||
.sp 1
|
||||
3. Display power readings in csv format and in stream mode.
|
||||
.nf
|
||||
.ft CW
|
||||
# zpwr --format csv --stream
|
||||
"iteration","time","time_epoch_sec","time_epoch_nsec","update_interval","cpu","storage","io","total","unassigned_resources","infrastructure"
|
||||
"0","2025-01-08 07:17:05+0100","1736317025","592784684","10000000000","143000000","1708200","40000000","15550000000","7659162700","5337186700"
|
||||
"1","2025-01-08 07:17:15+0100","1736317035","592937261","10000000000","143000000","1708200","40000000","15533000000","7650389100","5328960300"
|
||||
.ft
|
||||