When zfcpdump is built you get a compile warning
zfcpdump.c: In function ‘init_sig’:
zfcpdump.c:307:24: warning: cast between incompatible function types from ‘void (* (*)(int, siginfo_t *, void *))(int)’ {aka ‘void (* (*)(int, struct <anonymous> *, void *))(int)’} to ‘void (*)(int)’ [-Wcast-function-type]
g.sigact.sa_handler = (__sighandler_t)dump_sig_handler;
Furthermore the man pages for sigaction says
$man 2 sigaction
[...]
If SA_SIGINFO is specified in sa_flags, then sa_sigaction (instead
of sa_handler) specifies the signal-handling function for signum.
This function receives three arguments, as described below.
[...]
Because SA_SIGINFO is set, using sa_handler at all is wrong in this case.
Fix this by giving dump_sig_handler the correct return type and assign it
to sa_sigaction.
Signed-off-by: Philipp Rudo <prudo@linux.ibm.com>
Reviewed-by: Steffen Maier <maier@linux.ibm.com>
Signed-off-by: Jan Höppner <hoeppner@linux.ibm.com>