Open CAS Framework

Content:

Architecture overview

Intel(R) Cache Acceleration Software (CAS) consists of:

  • Platform independent library called Open CAS Framework (OCF)
  • Platform dependent adaptation layers enabling OCF to work in different environments such as Linux kernel

An example usage for OCF is Linux kernel (see picture below). In this case OCF operates as block level cache for block devices. For this usage model OCF comes with following adaptation layers:

  • Library client (top adapter) - its main responsibility is creating cache volume representing primary storage device. Application can read/write from/to the cache volume block device as to regular primary storage device.
  • Block device data object (bottom adapter) - is responsible for issuing IO operations to underlying block device.

A system administrator can manage cache instances via Intel CAS CLI management utility called "casadm".

OCF Linux deployment view

Another example of OCF usage is user space block level cache for QEMU (see picture below). In this example following adaptation layers may exist:

  • CAS virtIO-blk driver for QEMU (top adapter) - it exposes primary storage device (another virtIO driver) to guest OS via OCF library
  • virtIO-blk data object (bottom adapter) - enables OCF to access data on primary storage device or cache device via original virtIO driver

Please note that actual adapters depend on the environment where OCF is meant to be run. There can be different bottom adapters delivered for cache device and primary storage device. For example bottom adapter for caching device may be implemented using kernel bypass techniques, providing low-latency access to cache media.

OCF deployment in QEMU example

Management interface

Management interface delivered with Intel OCF enables system administrator to:

  • Configure OCF caching library to target environment, which includes installation of required platform dependent adapters.
  • Starting/stopping and managing existing cache instances.
  • Performing observability functions (e.g. retrieving performance counters)

For more details please see below examples:

Library initialization example

OCF enables possibility use it simultaneously from two independent libraries linked into the same executable by means of concept of contexts. Each context has its own set of operations which allow to handle specific data types used by data objects within this context.

#include "ocf.h"

/* Handle to library context */
ocf_ctx_t ctx;

/* Your context interface */
const struct ocf_ctx_ops ctx_ops = {
/* Fill your interface functions */
};

/* Your unique data object type IDs */
enum my_data_obj_type {
	my_data_obj_type_1,
	my_data_obj_type_2
};

/* Your data objects interface declaration */
const struct ocf_data_obj_ops my_data_obj_ops1 = {
	.name = "My data object 1",
	/* Fill your data object interface functions */
};

const struct ocf_data_obj_ops my_data_obj_ops2 = {
	.name = "My data object 2"
	/* Fill your data object interface functions */
};

int my_cache_init(void)
{
	int result;

	result ocf_ctx_init(&ctx, &ctx_ops)
	if (result) {
		/* Cannot initialze context of OCF library */
		return result;
	}
	/* Initialization successful */

	/* Now we can register data objects */
	result |= ocf_ctx_register_data_obj_ops(ctx, &my_data_obj_ops1,
			my_data_obj_type_1);
	if (result) {
		/* Cannot register data object interface */
		goto err;
	}

	result |= ocf_ctx_register_data_obj_ops(ctx, &my_data_obj_ops2,
			my_data_obj_type_2);
	if (result) {
		/* Cannot register data object interface */
		goto err;
	}

	return 0;

err:
	/* In case of failure we destroy context and propagate error code */
	ocf_ctx_exit(ctx);
	return result;
}

Cache management

OCF library API provides management functions (@ref ocf_mngt.h). This interface enables user to manage cache instances. Examples:

  • Start cache
int result;
ocf_cache_t cache; /* Handle to your cache */
struct ocf_mngt_cache_config cfg; /* Your cache configuration */

/* Prepare your cache configuration */

/* Configure cache mode */
cfg.cache_mode = ocf_cache_mode_wt;

/* Now tell how your cache will be initialzed. Selech warm or cold cache */
cfg.init_mode = ocf_init_mode_init;

cfg.uuid.data = "/path/to/your/cache/or/unique/id";

/* Specify cache data object type */
cfg.data_obj_type = my_data_obj_type_1;

/* Other cache configuration */
...

/* Start cache. */
result = ocf_mngt_cache_start(cas, &cache, cfg);
if (!result) {
	/* Your cache was created successfully */
}
  • Add core (primary storage device) to cache
int result;
ocf_core_t core;  /* Handle to your core */
struct ocf_mngt_core_config cfg; /* Your core configuration */

/* Prepare core configuration */

/* Select core data object type */
cfg.data_obj_type = my_data_obj_type_2;
/* Set UUID or path of your core */
cfg.uuid.data = "/path/to/your/core/or/unique/id";

result = ocf_mngt_cache_add_core(cache, &core, &cfg);
if (!result) {
	/* Your core was added successfully */
}

Management interface considerations

Each device (cache or core) is assigned with ID, either automatically by OCF or explicitly specified by user. It is possible to retrieve handle to cache instance via @ref ocf_cache_get_id. To get handle to core instance please use @ref ocf_core_get_id.

Cache management operations are thread safe - it is possible to perform cache management from many threads at a time. There is a possiblity to "batch" several cache management operations and execute them under cache management lock. To do this user needs to first obtain cache management lock, perform management operations and finally release the lock. For reference see example below.

int my_complex_work(ocf_cache_id_t cache_id,
		ocf_core_id_t core_id)
{
	int result;
	ocf_cache_t cache; /* Handle to your cache */
	ocf_core_t core; /* Handle to your core */

	/* Get cache handle */
	result = ocf_mngt_cache_get(cas, cache_id, &cache);
	if (result)
		return result;

	/* Lock cache */
	result = ocf_mngt_cache_lock(cache);
	if (result) {
		ocf_mngt_cache_put(cache);
		return result;
	}

	/* Get core handle */
	result = ocf_core_get(cache, core_id, &core);
	if (result) {
		result = -1;
		goto END;
	}

	/* Cache is locked, you can perform your activities */

	/* 1. Flush your core */
	result = ocf_mngt_core_flush(cache, core_id, true);
	if (result) {
		goto END;
	}

	/* 2. Your others operations including internal actions */

	/* 3. Removing core form cache */
	result = ocf_mngt_cache_remove_core(cache, core_id, true);

END:
	ocf_mngt_cache_unlock(cache); /* Remember to unlock cache */
	ocf_mngt_cache_put(cache); /* Release cache referance */

	return result;
}

IO path

Please refer to below sequence diagram for detailed IO flow. Typical IO path includes:

  • IO allocation - creating new IO instance that will be submitted to OCF for processing
  • IO configuration - specifying address and length, IO class, flags and completion function
  • IO submission - actual IO submission to OCF. OCF will perform cache lookup and based on its results will return data from cache or primary storage device
  • IO completion - is signalled by calling completion function specified in IO configuration phase

An example of IO flow

IO submission example

#include "ocf.h"

void read_end(struct ocf_io *io, int error)
{
	/* Your IO has been finished. Check the result and inform upper
	 * layers.
	 */

	/* Release IO */
	ocf_io_put(io);
}

int read(ocf_core_t core, void *data, addr, uint32_t length)
{
	/* Allocate IO */
	struct ocf_io *io = ocf_new_io(core);

	if (!io) {
		/* Cannot allocate IO */
		return -ENOMEM;
	}

	/* Configure IO, set address, flags, IO class, and etc... */
	ocf_io_configure(io, addr, length, OCF_READ, 0, 0);

	/* Set completion context and function */
	ocf_io_set_cmpl(io, NULL, NULL, read_end);

	/* Set data */
	if (ocf_io_set_data(io, data, 0)) {
		ocf_io_put(io);
		return -EINVAL;
	}

	/* Send IO requests to the cache */
	ocf_submit_io(io);

	/* Just it */